DELTA VFD C2000 MANUAL PDF

AC input power must be disconnected before any wiring to the AC motor drive is made. Please do nottouch the internal circuit and components. There are highly sensitive MOS components on the printed circuit boards. Thesecomponents are especially sensitive to static electricity.

Author:Vokus Dirg
Country:Mongolia
Language:English (Spanish)
Genre:Science
Published (Last):21 December 2016
Pages:31
PDF File Size:9.41 Mb
ePub File Size:5.18 Mb
ISBN:292-5-27256-578-7
Downloads:74618
Price:Free* [*Free Regsitration Required]
Uploader:Vizahn



Quick Links. See also: User Manual. Table of Contents. Classical field oriented control ac motor drive pages. High performance user-friendly powerful ac motor drives pages. High-performance low-noise general purpose ac motor drives 86 pages. Storage longer than one year is not recommended, it could result in the degradation of the electrolytic capacitors.

NOTE The content of this manual may be revised without prior notice. Page 5 Pr. Then the RFI capacities filter capacitors will be disconnected from ground to prevent circuit damage according to IEC and reduce earth leakage current. When installing one drive below another one, use a metal separation between the AC motor drives to prevent mutual heating and to prevent the risk of fire accident.

The minimum mounting clearances stated in the table above applies to AC motor drives frame A to D. A drive fails to follow the minimum mounting clearances may cause the fan to malfunction and heat dissipation problem. In order to retain the warranty coverage, the AC motor drive should be stored properly when it is not to be used for an extended period of time. It is now Loosen the 10 screws on the pallet, remove the ready for installation.

Lift the drive by hooking the lifting hole. It is now ready for installation. Remove the crate cover, EPEs, rubbers and manual. Loosen the 8 screws on the pallet as shown in the Loosen the 10 screws on the pallet and remove the following figure.

As shown in figure below. It is now Lift the drive by hooking the lifting hole. It is now ready for installation ready for installation.

Loosen the 6 screws on the top then remove 6 Loosen the 6 screws on the top then remove 6 metal washers and 6 plastic washers as shown in metal washers and 6 plastic washers as shown in figure below. Skip to the next step if this situation does not apply to you. Loosen 8 of M8 screws on the both sides and place the 2 plates that were removed from the last step. Loosen the 6 screws on the cover, remove 6 metal washers and 6 plastic washers as shown in below: Loosen 6 of the M6 screws on the side and removes the 2 plates, as shown in following figure.

Secure the drive from the external. Loosen 18 of the M6 screws and remove the top Loosen 8 of the M8 screws on the both sides and cover as shown in figure 2. Mount the cover figure Page 44 Chapter 3 Unpacking C Series Ensure the lifting hook properly goes through the Ensure the angle between the lifting holes and the lifting hole, as shown in the following diagram.

Please read following precautions before wiring. Failure to comply may result in damage to the equipments. If in your case the drives are in different power range, please contact with us Delta Industrial Automation Business Unit. Wire Torque Models Min. Page 64 Chapter 6 Control Terminals C Series Chapter 6 Control Terminals Please remove the top cover before wiring the multi-function input and output terminals, The drive appearances shown in the figures are for reference only, a real drive may look different.

Remove the cover for wiring. Page 66 Chapter 6 Control Terminals C Series Wiring precautions: Reserves 5mm and properly install the wire into the terminal; fasten the installation by a slotted screwdriver.

If the wire is stripped, sort the wire before install into the terminal. Flathead screwdriver: blade width 3. Output Frequency Pr. If the noise is inductive, connecting the shield to terminal ACM can bring improvement. Please select an applicable accessory according to your need or contact the local distributor for suggestion. Page 72 If damage to the drive or other equipment is due to the fact that the brake resistors and brake modules in use are not provided by Delta, the warranty will be void.

Take into consideration the safety of the environment when installing the brake resistors. If the minimum resistance value is to be utilized, consult local dealers for the calculation of Watt figures. Use only the fuses comply with local regulations. Page 75 Chapter 7 Optional Accessories C Series AC Reactor When the AC Motor Drive is connected directly to a large-capacity power transformer kVA or above or when a phase lead capacitor is switched, excess peak currents may occur in the power input circuit due to the load changes and the converter section may be damaged.

Problem: When applying power to one of the AC motor drive, the charge current of the capacitors may cause voltage dip. The reactor Wire Size mm Wiring type Qty. By using an EMI filter with correct installation, much interference can be eliminated. Page 81 Chapter 7 Optional Accessories C Series Saddle on both ends Saddle on one end Figure 2 The length of motor cable When motor is driven by an AC motor drive of PWM type, the motor terminals will experience surge voltages easily due to components conversion of AC motor drive and cable capacitance.

Page 87 Chapter 7 Optional Accessories C Series Conduit Box Installation Frame D Loosen the cover screws and press the tabs on each side of the cover to remove the cover, as shown in the following figure. Fasten the 6 screws shown in the following figure and place the cover back to the original position. Page 89 Chapter 7 Optional Accessories C Series Frame F Loosen the cover screws and press the tabs on each side of the cover to remove the cover, as shown in the following figure.

Install the conduit box by fastens the 4 screws, as shown in the following figure. On the drive, loosen 4 of the cover screws and press the tabs on each side of the cover to remove the cover, as shown in the following figure.

Place the cover back to the top and fasten the screws as shown in the figure. The arrow As shown below. Page 96 Chapter 7 Optional Accessories C Series Figure 1 Loosen screw 1 and screw 2, press the on the Figure 2 Loosen screw 3 and screw 4, press the tab on right and the left to remove the cover, follow the direction the right and the left to remove the cover.

Page 97 Chapter 7 Optional Accessories C Series Loosen screw 1 and screw 2 as shown in the figure below , and disconnect fan power before removing the fan. Loosen 8 screws and remove Fixture 2 as shown in 2.

Loosen 10 screws and remove Fixture 1 as shown the following figure. Fasten 4 screws as shown in the following figure. Loosen 12 screws and remove Fixture 2. Page RJ in RS connector for users to wire conveniently. LED Display 1. Blinking orange LED: data is transmitting. To prevent drive damage during installation, please removes the digital keypad and the cover before wiring.

Refer to the following instruction. Do not run control wires parallel to any high voltage AC power line V and above. Recommended wire size 0. Card RJ connection port Supports user diagnosis function. Auto-detects baud rates; supports Max. Product Profile 1. NET indicator 2. POWER indicator 3. Positioning hole 4. Switch off the power supply of VFD-C Remove the two screws see Figure 6.

Twist opens the card clip and inserts the slot type screwdriver to the hollow to prize the PCB off the card clip see Figure 7. The salt in the air must be less than 0. Detail Parameter 7. PC Link 2. Copy Parameter 8. Display Setup 3. Keypad Locked 9. Time Setup 4. Page Startup page can only display pictures, no flash. When Power ON, it will display startup page then the main page. When the selected item is U page, use left key and right key to switch between the items, the display order of U page is set by Pr.

Default 1 : roll down the page for more options 2. Default 2 3. User define Press for more options.

Pr setup : show complete se ntence System Pr Press for complete information Basic When the setting is complete, the date will be written to the copy parameters Pr page. Copy pr 1. When the setting is complete, the date will be written to the Copy PLC page. Copy PLC 1.

CSUNITEC COM PRICELIST PDF

Delta C2000 series User Manual

.

AL CALOR DEL TROPEL CARLOS MEDINA PDF

Delta C2000 Programming Manual

.

FELLOWES POWERSHRED 125CI PDF

Delta C2000-User-Manual

.

Related Articles